一定牛彩票

Position> 一定牛彩票 > Fire Door Products > Text
单扇钢质防火门
  • product name:

    Single leaf steel fire door

  • Fire resistance grade: Grade A, B, C
  • Material: Galvanized steel
  • Filler: refractory (such as perlite)
  • Optional colors: (The following colors are subject to the actual product and can be customized according to customer requirements)
    户外白亚光白亚光灰白
    乳白浅灰中灰
    驼皱红胡桃转印(户内)黑胡桃转印(户内)

Product description

Product features of double leaf steel fire door:

The double steel fire door is divided by two doors. The width of the door is generally above 1.2 or 1.5 meters. There is no bright light and no window. The structure design is reasonable. It is beautiful and elegant. At the same time, it has a certain anti-theft effect and is widely used in various industrial buildings, such as computer rooms, power distribution rooms, industrial workshops and other places where steel fire doors are required.

Product description of double leaf steel fire door:

The steel fire door adopts high-quality galvanized steel sheet, and the inside of the door body is filled with heat-resistant and refractory materials. The workmanship is exquisite, and the product quality reaches the national standard of GB12955-2008 fire door. Equipped with the national fire testing agency qualified hardware accessories. The surface is painted with paint and colors are available. The size of the door body can be tailored according to user needs, fully respecting the wishes of users.

Components of a double steel fire door:

The whole set of steel fire door is composed of door frame, door leaf, fire lock, fire door closer, fire hinge, fire latch, fire seal and sequencer (optional). According to the need, it is also possible to inlay and install Class A composite fireproof glass on the opening of the door leaf to make fireproof viewing windows, and install Class A composite fireproof glass on the upper part of the door frame to make fireproof bright windows.

Classification and grade of steel fire doors:

Steel fire doors are divided into single fire door, double fire door, single fire door with glass, double fire door with glass, single fire door with bright window, double fire door with bright window, single fan There are eight types of fire doors with glass and bright windows and double-leaf fire doors with glass and bright windows. Doors with a width of 1-1.2 meters can be made into child-type fire doors. According to the fire resistance limit, it is divided into three grades A, B, and C. The required fire resistance time is 1.5h for steel A fire door, 1.0h for steel B fire door, and 0.5h for steel C fire door.

Steel fire door use parts:

Products are mainly used in basements, external evacuation stairs, power equipment rooms, elevator control rooms, machine rooms, industrial buildings, etc.

Second, purchase notice

Due to the different materials and specifications of various doors, the specific data confirmed with our customer service shall prevail! In addition, due to many product styles and colors, please contact customer service for more product styles!

Fire doors are particularly important as the first level of home fire protection , but when you buy a poor quality fire door, the fire door no longer fires. What should you do? Some unscrupulous manufacturers use honeycomb paper as a substitute for fire-resistant filling materials, which is cheap and does not play a fire-proof role at all. This is a joke in our lives. When we buy, the hardware accessories must also be fire-resistant hardware accessories.

There are five major ways to buy quality fire doors:

The first measure is to check the appearance . The high-quality steel \ fire door is firmly welded, and the welding points are evenly distributed. The outer surface is sprayed flat and smooth. The product mark, quality inspection qualified mark and quality certification (approval) qualified mark should be displayed at the specified position. The appearance of a qualified wooden fire door should be complete, without damage, with a clean surface, without planing marks, burrs, and hammer marks; cut corners and seams should be tight and smooth.

The second measure is the number . The overall dimensions of the qualified product should be less than or equal to the dimensions in the sample description. The thickness of the door leaf should be greater than or equal to the thickness of the door leaf in the sample description. The width of the door frame side wall should be greater than or equal to the width of the door frame side wall in the sample description. The overall dimensions of the fire-resistant glass shall be less than or equal to the outer dimensions of the fire-resistant glass as described in the sample description, and the thickness of the fire-resistant glass shall be greater than or equal to the thickness of the fire-resistant glass as described in the sample description.

The third measure is to look at the seals . Fireproof seals should be provided for qualified steel and wooden fire doors. The seals should be straight, without arches, and have a qualified test report issued by a national testing agency.

The fourth measure is to estimate the weight . Fire doors with qualified quality are generally heavier, while those with very light fire doors must be of inferior quality.

The fifth measure is to check the certificate . The fire door is a product that is included in the type approval system. Before the product is sold, it needs to undergo type inspection. The general type inspection report details the specifications, dimensions, composition, materials, and photos of the product. The type inspection report should be obtained from the manufacturer when the actual purchase.

Third, fire door installation

1. Door frame installation :

1.1 In order to ensure that the door frame can be adjusted freely in the opening, the opening should be trimmed to ensure that the front and side of the door frame are vertical to the ground;

1.2 The fixed door frame is connected to the wall with iron nails or expansion bolts, and steel fire doors are reserved for expansion bolt holes for installation;

1.3 The installation of door frames without lower frames should ensure that the opening direction of the doors is the evacuation direction. For a large number of fire doors on the same plane, a straight line should be drawn at both ends to ensure that the door frames are on the same plane and have the same height.

1.3.1. Measure the level of the upper frame with a thin horizontal tube during installation, and adjust the frame to the vertical ground with a wire drop or a ruler. The door frame must be firmly fixed, but the nail must be kept 1cm. When the door is installed, nail it to the end. Be careful not to damage the door frame when nailing.

1.3.2 After the door frame is fixed, ensure the following:

① Use a horizontal ruler to measure the verticality error of the two sides of the two frames ≤1mm / m;

② Use the inner and outer right angle detection ruler to detect the right angle error of the two vertex angles of the inner notch ≤1mm;

③ Use a steel tape measure to measure the upper and lower deviation of the inner slot ≤ 1mm, and check that the diagonal deviation should not be greater than 3mm.

2. Door leaf installation :

2.1. When installing wooden doors, check whether the size of the door leaf is consistent with the door frame. Determine the hinge position on the frame leaf. It is strictly forbidden to open the hinge groove on one side. The depth of the hinge groove on the frame is the same as the thickness of the hinge.

(2) After the hinges are installed, they are parallel to the frame;

(3) The hinge slot is suitable in depth, the position is suitable, the door gap is even, and the switch is flexible without flipping the fan;

(4) The hinge groove is on the same plane.

2.2 After the door is installed, the following points should be guaranteed during commissioning:

(1) Check the gap of the door leaf with a feeler gauge;

(2) Check and confirm the height difference between the front surface of the frame and the fan;

(3) The door leaf switch is flexible, and the rebound amount is checked and confirmed.

Fourth, the authority test certificate / report


3C Compulsory Certification3C Compulsory Certification3C Compulsory CertificationTest ReportTest ReportTest Report

V. Three major production bases (Cangzhou Branch, Wangdu Branch, Baoding Branch)


Factory buildingRaw material warehouse

Project case

Beijing Olympic Sports CenterWanda squareEvergrande Real Estate
Beijing Olympic Sports Center Wanda square Evergrande Real Estate
Ordos AirportChina University of GeosciencesAlibaba Group
Ordos Airport China University of Geosciences Alibaba Group

Seven, steel fire door detailed parameters

Executive standard: GB 12955-2008 "Fire Door";

Fire resistance: 1.5h for Grade A, 1.0h for Grade B, 0.5h for Grade C;

Galvanized steel: fan plate thickness ≥0.8mm, frame plate thickness ≥1.2mm;

Door leaf fireproof glass general transmission size: 125mmx935mm Maximum transmission size: 140mmx1490mm Glass bead without screw connection, glass bead can be made of aluminum alloy;

The door frame can be used for interior, exterior, and buckle edges, with optional straight edges and lace;

Features: high strength, anti-humidity and anti-theft;

Precautions: prevent perlite from eroding the door panel in water;

Fire door legend:

Fire door legend

Recommended articles

防火门十大品牌
Hebei Jiu'an Fire Door Manufacturing Group Co., Ltd. <br /> China's Top Ten Brand Fire Door Sales Hotline: 400-0312-700 0312-5971018
Company Fax: 0312-5971010
Address of Company: No.531 Fengqi Street, Private Science and Technology Industrial Park, Qiyi East Road, Baoding, Hebei Province
var _hmt = _hmt || []; (function() { var hm = document.createElement("script"); hm.src = "https://hm.baidu.com/hm.js?be055eb5acfdc25d3bd72279b8418725"; var s = document.getElementsByTagName("script")[0]; s.parentNode.insertBefore(hm, s); })();